10.1 Wizard

Accessible via: Section 7.4, “Main menu”

NOTICE

The wizard overwrites actual channel settings!

The wizard runs for selected channels. If no channel is selected at the start of the wizard, you can mark all channels on request.

The wizard includes the following steps
  1. Channels will be reset to its factory defaults.
  2. The lower current limits and upper current limits of the channels are determined.
  3. Channels without load are disabled and removed from the further assistant function. The following steps affect only channels to which the tool is connected.
  4. A basic setting can be made for all selected channels (Factory defaults can be adjusted at “Device” / “Wizard settings” and “Basic settings”).

Adaptation

Adaptation determines the control behavior of the heating zone. It takes place in two phases:

Heating up:: It is heated up for a maximum of 2 minutes or until the temperature rises to 10 K. This phase is displayed with adaptation 1.

Cooling down:: The channel is disabled. It is waited until the temperature has fallen at least 5 K below the maximum or 10 minutes have been elapsed. This phase is displayed with adaptation 2.