9.2 Device settings

Accessible via: Section 7.4, “Main menu”

(1)Submenus that can be opened and closed by clicking.
(2)Display and change of device settings.
(3)Language setting. Contact customer service for additional language files available!
(4)Reset to factory settings. Selection whether for the complete device or only basic setting for channels and wizard.
(5)Main contacter On (red lightning symbol) or OFF (white lightning symbol). When the main contactor is switched on, the channels are live. Now, the mold connector can be powered on!
(6)Channel sorting. The channels can be sorted in the “Overview” according to the physical arrangement of the tool plug. Please contact our customer service.
(7)Use these buttons to navigate through the submenus.
(8)Use these buttons to navigate up and down.

9.2.1 Language

The Language button in the footer opens the “Select language and restart system” dialog. It lists the languages present on this device; the active one is ticked. A selection takes effect immediately and restarts the user interface — control keeps running, but the display cannot be operated for a few seconds.

9.2.2 Device

DeviceDisplay of the installed firmware version.
Serial numberThermonom serial number [serial number of the display board].
SpeakerSwitching ON or OFF of signal tones when operating.
Time / dateChange the time zone or set the time/date manually. On delivery, and after clicking the “Automatic” button, the time/date is retrieved from the internet if a connection is available.
ScreensaverThe screensaver turns off if the device has not been operated within the specified time.
Automatic logout timeAutomatic logout of users after a definable time without device operation.
Automatically startAutostart of the device after loss of power (ON, OFF, after 0..3600 s).
Phase current limitSet the maximum desired power consumption of the device [maximum value set by infeed]. The device derives from this value the current budget with which it switches the channels on in stages, see Section 6.8, “Power limits and power reduction”.
Residual current limitThe device has an internal residual current measurement. The standard permissible difference is 200 mA. This limit can be reduced, increased or deactivated with a given sensitivity. For how the device reacts to a residual current, see Section 6.10, “Groups, substitution and failures”.
Residual currentDisplays the sum of the currently measured fault currents of all channels.
Compensation pointSelect the source of the reference temperature. The internal reference is selected by default; if you have installed an external sensor on your mould cable, you can switch to this temperature and omit the compensation wire in the mould cable. Ask customer service to purchase the required hardware.
Compensation temperatureDisplay of the available compensation temperatures.

9.2.3 Basic settings

In the basic settings you can set standard values for all channels of a device. These settings are adopted by the wizard or by resetting the channels to basic settings. This is useful if you want to reset the individually set values in the channel settings. Detailed explanations of the values can be found at Section 9.1, “Channel settings”.

9.2.4 Wizard settings

In this subitem you can set special specifications for the wizard.

Current limits
According to which system should the current limits be set? See Section 9.1, “Channel settings” / “Current”
Adaptation
See “Adaptation”
Start channel after wizard
After the wizard, the channels are switched on automatically.

9.2.5 Network settings

At this point you can activate the DHCP function of the hot runner controller to enable an automatic IP assignment by your router. Alternatively, you can deactivate DHCP if you want to assign a static IP.

9.2.6 WIFI settings

You can make the WIFI settings here. Display available networks, enter passwords and manage connections. You will need additional hardware for this, which you can obtain from our customer service.

9.2.7 Coupling

The channels of several hot runner controllers can be combined into a cross-device operating and processing unit. That means molds can be operated that require more heating channels than the maximum number of channels per device.

Step 1 - Physical coupling
Coupling of several Thermonom hot runner controller takes place via connector X2 (LAN port) on the back side of the device:

NOTE

Also note the assignment of the IP (static or via DHCP). The devices can only be coupled if you are in the same subnet!
Step 2 - Virtual coupling
Make settings in the “Device”-“Coupling” view. Only if there are several devices in the same physical network, they can be coupled via one of the six virtual networks. Devices can be in different virtual networks, even if they are in the same physical network.
CouplingDisplay of the summary of the coupling settings.
NetworkThe device joins one of the networks shown. All devices in the same network are automatically coupled. With “No coupling” the coupling of the device is released again.
Desired positionWhen connecting devices, all channels can be processed by each device. The channels of each device are displayed in the “Overview” and “Monitor” and can be selected for further processing. The position in this display is specified here. If the value is lower, the channels of the device are shown above.
Device name in networkDisplay of the device name (letter) in the “Overview” and “Monitor”, depending on the desired position.
Number of coupled devicesDisplays how many devices are coupled.

9.2.8 Inputs and outputs

9.2.9 Controller #

This is the name of the built-in controller boards of the hot runner control (e.g.: controller 0 (channel 1-6), controller 1 (channel 7-12)). The serial number, the firmware and hardware version, the temperature of the heat sink and the compensation point as well as the number of activated licenses (maximum 6 per controller) are displayed.

Table 7: Extensions

namedescriptionChangeable
(User level)
Serial numberSerial number of the controller unit
Firmware versionFirmware version of the controller unit. The firmware is automatically updated during software updates (“Software”-“update”).
Hardware versionHardware version of the controller unit.
Fault currentShows the sum of the fault current of the 6 channels in this controller unit. Only available from hardware revision 500.
Heat sink temperatureTemperature at the heat sink of the controller unit.
ADC temperatureTemperature on the circuit board of the controller unit.
LicensesCurrent number of licenses (maximum 6) for this controller unit. Enter a license code to activate additional channels at the same time.Yes ( #3 )

NOTE

If you have purchased a device without full license equipment, you can enter the purchased activation code for additional licenses here (click on the number next to “Licenses”)

9.2.10 Extensions

Device extensions can be created and configured in this submenu.

To do this, click on “Create new extension”! You can then choose from the following list:

Table 8: Extensions

NameDescription
Arburg TTYA 20mA TTY interface can be activated on the D-Sub connector, this allows remote control of the Thermonom by a higher-level system. Additional hardware is required for this function, please contact customer service. To select the serial interfaces, please refer to Section 4.4.2, “Assignment of X4 D-Sub 9-pins”.
Modbus ClientEnables access to a subordinate system via Modbus. For example, to read in analog values or set outputs. Additional software is required for this, please contact customer service and explain your requirements!
Modbus TCP ServerEnables access from a higher-level system via Modbus.
OPC UA ServerEnables access from a higher-level system via OPC UA. For setup, endpoint and data endpoints see Chapter 12, “OPC UA interface”.
RFID readerEnables the reading of RFID tags and the automatic loading of recipes or logging in of users. Additional hardware is required for this function, please contact customer service.
Your solutionNo solution available for your problem? Please contact the customer service and explain your wishes!

To delete a created extension, click on it and confirm the deletion process with “Yes”.

Interfaces

RS232, RS485 and CAN, for example, are connected via the D-Sub 9 connector (X4). You can use the “Arburg TTY” protocol. Please note that you need additional hardware for “Arburg TTY”! Please contact our customer service!

Click on “Create new extension” to set up a connection.

NOTE

Please be sure to observe Section 4.4.2, “Assignment of X4 D-Sub 9-pins”

Table 9: Interfaces on the Sub-D connector (X4)

ProtocolSetting option
Arburg TTYDevice address, physical output of the interface

ModbusTCP is fed out via the Ethernet connector (X2) as standard.

Table 10: Interfaces on the Ethernet connector (X2)

ProtocolSetting option
ModbusTCP (Server)port and mapping selectable

9.2.11 Thermonom-Cloud

With the Thermonom cloud, you have access to the data of your Thermonom devices from your PC. You will receive access data to the Thermonom cloud (https://thermonom.intronik.de/dashboard) via the customer service.

Then connect your Thermonom to the cloud. Access data is required for this. You can decide for yourself whether you want to activate or deactivate the service. Once the connection has been set up, establish the device-user pairing by creating a TOKEN on the PC in your cloud and entering it in the Thermonom .

NOTE

An internet connection (network cable or WLAN) is required for the Thermonom Cloud!

9.2.12 Advanced Settings

Start view
Specify whether “Overview” (12 channels) or Section 8.2, “Monitor” (24 to 96 channels) should be displayed as the start view.
System parameter
For special applications, it may be necessary to change other system settings. It is essential to consult Thermonom customer service for this.
System temperatures
Calibration start - Required for initial commissioning. Only for SERVICE.

9.2.13 Variables

Only for SERVICE.

The Customer-IO is a 8-pin plug on the back side of the device. 3 inputs and 2 outputs are available which can be assigned with operating and display functions.

NOTE

Please refer to the circuit diagram in Figure 10.

Inputs

With the inputs you can set or reset some operating functions via switches. The inputs can be connected with 24 VDC or 240 VAC.

NOTE

A command will only be executed if it is possible. This can be monitored via outputs.

Function

CommandInput is setInput is reset
ON / OFFThe channels are switched onThe channels are switched off
StandbyLowering of temperature takes placeThe lowering is ended = Temperature rises again to its setpoint
BoostThe set temperature is raised for the determined boost period and temperatureThe boost is canceled (Resetting after a completed boost period has no effect)
Delete errorAcknowledging of a fixed errorNo function

The commands can be canceled directly on the surface of the Thermonom hot runner control. This has no effect on the input logic.

Input logic
Example
You enable channels via a set input and disable them via the user interface of the Thermonom hot runner control. The input is still set but the channels are disabled. So now, reset the input which triggers the disable command, too. The channels remain disabled. That is the way when enabling, as well. It is possible to enable channels in the user interface without a set input. The channels remain enabled when the input is additionally set.

That means: There are no conflicts with simultaneous operation by inputs and surface.

Source

Select a group or device to which the function should be applied.

Condition

The physical condition of the input is used to check the connected circuits.

Invert

The physical state is inverted. For example: a rising edge at the input switches the heating zones off.

Pin assignment

Contacts of this input, graphical display of the pin assignment of the “Customer IO” connector.

Outputs

You can assign individual external functions to the outputs, for example, connect an optical and / or acoustic alarm.

Function

ON / OFF

Alarm At least one of the assigned channels indicates an alarm.

A disabled channel never reports an alarm.

Operational

All channels or all channels of the selected tool are at the set temperature. Injection can begin.

A disabled channel is always operational.

NOT operational
At least 1 channel is on
As soon as at least 1 channel of the selected reference is switched on, the output is set active.
All channels are off
As soon as all channels of the selected reference are switched off, the output is set to active.

Source

Select a group or device to which the function should be applied.

Condition

The physical state is inverted.

Invert

The physical state is inverted. For example: a rising edge at the input switches the heating zones off.

Contacts

Contacts of this output, graphical display of the pin assignment of the “Customer IO” connector.